Heated Alfresco Structures
Square
Rectangular
Truncated
Square
Model: S 9.0 - 4
81 sq ft
8 Persons
Model: S 10.7 - 4
112 sq ft
12 Persons
Model: S 12.5 - 4
153 sq ft
16 Persons
Model: S 12.5 - 8
153 sq ft
16 Persons
Model: S 13.6 - 8
181 sq ft
20 Persons
Model: S 15.1 - 8
228 sq ft
24 Persons
Model: S 15.1 - 12
228 sq ft
24 Persons
Model: S 16.8 - 8
277 sq ft
28 Persons
Model: S 16.8 - 12
277 sq ft
28 Persons
Model: S 17.8 - 16
314 sq ft
32 Persons
Return to Shape Selection ( Step 2 )
Floor Coverage:
81 sq ft
81 sq ft
Seating Capacity:
8 Persons
8 Persons
Dimensions:
9' (L)
9' (W)
11' (H)
9' (L)
9' (W)
11' (H)
Heating System:
4 x Non Glowing Radiant Panels
with 2-stage heat output
4 x Non Glowing Radiant Panels
with 2-stage heat output
Lighting System:
4 x Dimmable LED fixtures
4 x Dimmable LED fixtures
Electrical Power:
4.8kW (high heat)
2.4kW (low heat)
4.8kW (high heat)
2.4kW (low heat)
Electrical Current Loads:
@ 1-phase 120Volt
40A (high) 20A (low)
@ Split-phase 240Volt
20A (high) 10A (low)
@ 3-phase 208Volt (4-Wire WYE)
13.4 A (high) 6.7A (low)
@ 1-phase 120Volt
40A (high) 20A (low)
@ Split-phase 240Volt
20A (high) 10A (low)
@ 3-phase 208Volt (4-Wire WYE)
13.4 A (high) 6.7A (low)
Available Wind Ratings:
75mph
75mph
UV & Flame Resistant Fabrics:
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
Floor Coverage:
112 sq ft
112 sq ft
Seating Capacity:
12 Persons
12 Persons
Dimensions:
10' 7 ¼\" (L)
10' 7 ¼\" (W)
11' 3\" (H)
10' 7 ¼\" (L)
10' 7 ¼\" (W)
11' 3\" (H)
Heating System:
4 x Non Glowing Radiant Panels
with 2-stage heat output
4 x Non Glowing Radiant Panels
with 2-stage heat output
Lighting System:
4 x Dimmable LED fixtures
4 x Dimmable LED fixtures
Electrical Power:
4.8kW (high heat)
2.4kW (low heat)
4.8kW (high heat)
2.4kW (low heat)
Electrical Current Loads:
@ 1-phase 120Volt
40A (high) 20A (low)
@ Split-phase 240Volt
20A (high) 10A (low)
@ 3-phase 208Volt (4-Wire WYE)
13.4 A (high) 6.7A (low)
@ 1-phase 120Volt
40A (high) 20A (low)
@ Split-phase 240Volt
20A (high) 10A (low)
@ 3-phase 208Volt (4-Wire WYE)
13.4 A (high) 6.7A (low)
Available Wind Ratings:
75mph, 90mph
75mph, 90mph
UV & Flame Resistant Fabrics:
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
Floor Coverage:
153 sq ft
153 sq ft
Seating Capacity:
16 Persons
16 Persons
Dimensions:
12' 4 ½\" (L)
12' 4 ½\" (W)
11' 3\" (H)
12' 4 ½\" (L)
12' 4 ½\" (W)
11' 3\" (H)
Heating System:
4 x Non Glowing Radiant Panels
with 2-stage heat output
4 x Non Glowing Radiant Panels
with 2-stage heat output
Lighting System:
4 x Dimmable LED fixtures
4 x Dimmable LED fixtures
Electrical Power:
4.8kW (high heat)
2.4kW (low heat)
4.8kW (high heat)
2.4kW (low heat)
Electrical Current Loads:
@ 1-phase 120Volt
40A (high) 20A (low)
@ Split-phase 240Volt
20A (high) 10A (low)
@ 3-phase 208Volt (4-Wire WYE)
13.4 A (high) 6.7A (low)
@ 1-phase 120Volt
40A (high) 20A (low)
@ Split-phase 240Volt
20A (high) 10A (low)
@ 3-phase 208Volt (4-Wire WYE)
13.4 A (high) 6.7A (low)
Available Wind Ratings:
75mph, 90mph
75mph, 90mph
UV & Flame Resistant Fabrics:
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
Floor Coverage:
153 sq ft
153 sq ft
Seating Capacity:
16 Persons
16 Persons
Dimensions:
12' 4 ½\" (L)
12' 4 ½\" (W)
11' 3\" (H)
12' 4 ½\" (L)
12' 4 ½\" (W)
11' 3\" (H)
Heating System:
8 x Non Glowing Radiant Panels
with 2-stage heat output
8 x Non Glowing Radiant Panels
with 2-stage heat output
Lighting System:
4 x Dimmable LED fixtures
4 x Dimmable LED fixtures
Electrical Power:
9.6kW (high heat)
4.8kW (low heat)
9.6kW (high heat)
4.8kW (low heat)
Electrical Current Loads:
@ 1-phase 120Volt
80A (high) 40A (low)
@ Split-phase 240Volt
40A (high) 20A (low)
@ 3-phase 208Volt (4-Wire WYE)
26.8 A (high) 13.4A (low)
@ 1-phase 120Volt
80A (high) 40A (low)
@ Split-phase 240Volt
40A (high) 20A (low)
@ 3-phase 208Volt (4-Wire WYE)
26.8 A (high) 13.4A (low)
Available Wind Ratings:
75mph, 90mph
75mph, 90mph
UV & Flame Resistant Fabrics:
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
Floor Coverage:
181 sq ft
181 sq ft
Seating Capacity:
20 Persons
20 Persons
Dimensions:
13' 5 ½\" (L)
13' 5 ½\" (W)
11' 5\" (H)
13' 5 ½\" (L)
13' 5 ½\" (W)
11' 5\" (H)
Heating System:
8 x Non Glowing Radiant Panels
with 2-stage heat output
8 x Non Glowing Radiant Panels
with 2-stage heat output
Lighting System:
4 x Dimmable LED fixtures
4 x Dimmable LED fixtures
Electrical Power:
9.6kW (high heat)
4.8kW (low heat)
9.6kW (high heat)
4.8kW (low heat)
Electrical Current Loads:
@ 1-phase 120Volt
80A (high) 40A (low)
@ Split-phase 240Volt
40A (high) 20A (low)
@ 3-phase 208Volt (4-Wire WYE)
26.8 A (high) 13.4A (low)
@ 1-phase 120Volt
80A (high) 40A (low)
@ Split-phase 240Volt
40A (high) 20A (low)
@ 3-phase 208Volt (4-Wire WYE)
26.8 A (high) 13.4A (low)
Available Wind Ratings:
75mph, 90mph, 120mph
75mph, 90mph, 120mph
UV & Flame Resistant Fabrics:
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
Floor Coverage:
228 sq ft
228 sq ft
Seating Capacity:
24 Persons
24 Persons
Dimensions:
15' 1\" (L)
15' 1\" (W)
11' 8\" (H)
15' 1\" (L)
15' 1\" (W)
11' 8\" (H)
Heating System:
8 x Non Glowing Radiant Panels
with 2-stage heat output
8 x Non Glowing Radiant Panels
with 2-stage heat output
Lighting System:
4 x Dimmable LED fixtures
4 x Dimmable LED fixtures
Electrical Power:
9.6kW (high heat)
4.8kW (low heat)
9.6kW (high heat)
4.8kW (low heat)
Electrical Current Loads:
@ 1-phase 120Volt
80A (high) 40A (low)
@ Split-phase 240Volt
40A (high) 20A (low)
@ 3-phase 208Volt (4-Wire WYE)
26.8 A (high) 13.4A (low)
@ 1-phase 120Volt
80A (high) 40A (low)
@ Split-phase 240Volt
40A (high) 20A (low)
@ 3-phase 208Volt (4-Wire WYE)
26.8 A (high) 13.4A (low)
Available Wind Ratings:
75mph, 90mph, 120mph
75mph, 90mph, 120mph
UV & Flame Resistant Fabrics:
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
Floor Coverage:
228 sq ft
228 sq ft
Seating Capacity:
24 Persons
24 Persons
Dimensions:
15' 1\" (L)
15' 1\" (W)
11' 8\" (H)
15' 1\" (L)
15' 1\" (W)
11' 8\" (H)
Heating System:
12 x Non Glowing Radiant Panels
with 2-stage heat output
12 x Non Glowing Radiant Panels
with 2-stage heat output
Lighting System:
4 x Dimmable LED fixtures
4 x Dimmable LED fixtures
Electrical Power:
14.4kW (high heat)
7.2kW (low heat)
14.4kW (high heat)
7.2kW (low heat)
Electrical Current Loads:
@ 1-phase 120Volt
120A (high) 60A (low)
@ Split-phase 240Volt
60A (high) 30A (low)
@ 3-phase 208Volt (4-Wire WYE)
40 A (high) 20A (low)
@ 1-phase 120Volt
120A (high) 60A (low)
@ Split-phase 240Volt
60A (high) 30A (low)
@ 3-phase 208Volt (4-Wire WYE)
40 A (high) 20A (low)
Available Wind Ratings:
75mph, 90mph, 120mph
75mph, 90mph, 120mph
UV & Flame Resistant Fabrics:
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
Floor Coverage:
277 sq ft
277 sq ft
Seating Capacity:
28 Persons
28 Persons
Dimensions:
16' 7 ¾\" (L)
16' 7 ¾\" (W)
12' (H)
16' 7 ¾\" (L)
16' 7 ¾\" (W)
12' (H)
Heating System:
8 x Non Glowing Radiant Panels
with 2-stage heat output
8 x Non Glowing Radiant Panels
with 2-stage heat output
Lighting System:
4 x Dimmable LED fixtures
4 x Dimmable LED fixtures
Electrical Power:
9.6kW (high heat)
4.8kW (low heat)
9.6kW (high heat)
4.8kW (low heat)
Electrical Current Loads:
@ 1-phase 120Volt
80A (high) 40A (low)
@ Split-phase 240Volt
40A (high) 20A (low)
@ 3-phase 208Volt (4-Wire WYE)
26.8 A (high) 13.4A (low)
@ 1-phase 120Volt
80A (high) 40A (low)
@ Split-phase 240Volt
40A (high) 20A (low)
@ 3-phase 208Volt (4-Wire WYE)
26.8 A (high) 13.4A (low)
Available Wind Ratings:
75mph, 90mph, 120mph
75mph, 90mph, 120mph
UV & Flame Resistant Fabrics:
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
Floor Coverage:
277 sq ft
277 sq ft
Seating Capacity:
28 Persons
28 Persons
Dimensions:
16' 7 ¾\" (L)
16' 7 ¾\" (W)
12' (H)
16' 7 ¾\" (L)
16' 7 ¾\" (W)
12' (H)
Heating System:
8 x Non Glowing Radiant Panels
with 2-stage heat output
8 x Non Glowing Radiant Panels
with 2-stage heat output
Lighting System:
4 x Dimmable LED fixtures
4 x Dimmable LED fixtures
Electrical Power:
14.4kW (high heat)
7.2kW (low heat)
14.4kW (high heat)
7.2kW (low heat)
Electrical Current Loads:
@ 1-phase 120Volt
120A (high) 60A (low)
@ Split-phase 240Volt
60A (high) 30A (low)
@ 3-phase 208Volt (4-Wire WYE)
40 A (high) 20A (low)
@ 1-phase 120Volt
120A (high) 60A (low)
@ Split-phase 240Volt
60A (high) 30A (low)
@ 3-phase 208Volt (4-Wire WYE)
40 A (high) 20A (low)
Available Wind Ratings:
75mph, 90mph, 120mph
75mph, 90mph, 120mph
UV & Flame Resistant Fabrics:
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
Floor Coverage:
314 sq ft
314 sq ft
Seating Capacity:
32 Persons
32 Persons
Dimensions:
17' 8 ½\" (L)
17' 8 ½\" (W)
12' 1/8\" (H)
17' 8 ½\" (L)
17' 8 ½\" (W)
12' 1/8\" (H)
Heating System:
16 x Non Glowing Radiant Panels
with 2-stage heat output
16 x Non Glowing Radiant Panels
with 2-stage heat output
Lighting System:
4 x Dimmable LED fixtures
4 x Dimmable LED fixtures
Electrical Power:
19.2kW (high heat)
9.6kW (low heat)
19.2kW (high heat)
9.6kW (low heat)
Electrical Current Loads:
@ 1-phase 120Volt
160A (high) 80A (low)
@ Split-phase 240Volt
80A (high) 40A (low)
@ 3-phase 208Volt (4-Wire WYE)
53.4 A (high) 26.7A (low)
@ 1-phase 120Volt
160A (high) 80A (low)
@ Split-phase 240Volt
80A (high) 40A (low)
@ 3-phase 208Volt (4-Wire WYE)
53.4 A (high) 26.7A (low)
Available Wind Ratings:
75mph, 90mph, 120mph
75mph, 90mph, 120mph
UV & Flame Resistant Fabrics:
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
Floor Coverage:
131 sq ft
131 sq ft
Seating Capacity:
14 persons
14 persons
Dimensions:
12' 4 ½\" (L)
10' 6 ¾\" (W)
11' 3\" (H)
12' 4 ½\" (L)
10' 6 ¾\" (W)
11' 3\" (H)
Heating System:
4 x Non Glowing Radiant Panels
with 2-stage heat output
4 x Non Glowing Radiant Panels
with 2-stage heat output
Lighting System:
4 x Dimmable LED fixtures
4 x Dimmable LED fixtures
Electrical Power:
4.8kW (high heat)
2.4kW (low heat)
4.8kW (high heat)
2.4kW (low heat)
Electrical Current Loads:
@ 1-phase 120Volt
40A (high) 20A (low)
@ Split-phase 240Volt
20A (high) 10A (low)
@ 3-phase 208Volt (4-Wire WYE)
13.4 A (high) 6.7A (low)
@ 1-phase 120Volt
40A (high) 20A (low)
@ Split-phase 240Volt
20A (high) 10A (low)
@ 3-phase 208Volt (4-Wire WYE)
13.4 A (high) 6.7A (low)
Available Wind Ratings:
75mph, 90mph
75mph, 90mph
UV & Flame Resistant Fabrics:
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
Floor Coverage:
160 sq ft
160 sq ft
Seating Capacity:
16 persons
16 persons
Dimensions:
15' 1\" (L)
10' 7 ¼\" (W)
11' 10\" (H)
15' 1\" (L)
10' 7 ¼\" (W)
11' 10\" (H)
Heating System:
6 x Non Glowing Radiant Panels
with 2-stage heat output
6 x Non Glowing Radiant Panels
with 2-stage heat output
Lighting System:
4 x Dimmable LED fixtures
4 x Dimmable LED fixtures
Electrical Power:
7.2kW (high heat)
3.6kW (low heat)
7.2kW (high heat)
3.6kW (low heat)
Electrical Current Loads:
@ 1-phase 120Volt
60A (high) 30A (low)
@ Split-phase 240Volt
30A (high) 15A (low)
@ 3-phase 208Volt (4-Wire WYE)
20 A (high) 10A (low)
@ 1-phase 120Volt
60A (high) 30A (low)
@ Split-phase 240Volt
30A (high) 15A (low)
@ 3-phase 208Volt (4-Wire WYE)
20 A (high) 10A (low)
Available Wind Ratings:
75mph, 90mph, 120mph
75mph, 90mph, 120mph
UV & Flame Resistant Fabrics:
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
Floor Coverage:
160 sq ft
160 sq ft
Seating Capacity:
16 persons
16 persons
Dimensions:
15' 1\" (L)
10' 7 ¼\" (W)
11' 10\" (H)
15' 1\" (L)
10' 7 ¼\" (W)
11' 10\" (H)
Heating System:
8 x Non Glowing Radiant Panels
with 2-stage heat output
8 x Non Glowing Radiant Panels
with 2-stage heat output
Lighting System:
4 x Dimmable LED fixtures
4 x Dimmable LED fixtures
Electrical Power:
9.6kW (high heat)
4.8kW (low heat)
9.6kW (high heat)
4.8kW (low heat)
Electrical Current Loads:
@ 1-phase 120Volt
80A (high) 40A (low)
@ Split-phase 240Volt
40A (high) 20A (low)
@ 3-phase 208Volt (4-Wire WYE)
26.8 A (high) 13.4A (low)
@ 1-phase 120Volt
80A (high) 40A (low)
@ Split-phase 240Volt
40A (high) 20A (low)
@ 3-phase 208Volt (4-Wire WYE)
26.8 A (high) 13.4A (low)
Available Wind Ratings:
75mph, 90mph, 120mph
75mph, 90mph, 120mph
UV & Flame Resistant Fabrics:
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
Floor Coverage:
216 sq ft
216 sq ft
Seating Capacity:
22 persons
22 persons
Dimensions:
17' 5 ¾\" (L)
12' 4 ½\" (W)
12' 1\" (H)
17' 5 ¾\" (L)
12' 4 ½\" (W)
12' 1\" (H)
Heating System:
8 x Non Glowing Radiant Panels
with 2-stage heat output
8 x Non Glowing Radiant Panels
with 2-stage heat output
Lighting System:
4 x Dimmable LED fixtures
4 x Dimmable LED fixtures
Electrical Power:
9.6kW (high heat)
4.8kW (low heat)
9.6kW (high heat)
4.8kW (low heat)
Electrical Current Loads:
@ 1-phase 120Volt
80A (high) 40A (low)
@ Split-phase 240Volt
40A (high) 20A (low)
@ 3-phase 208Volt (4-Wire WYE)
26.8 A (high) 13.4A (low)
@ 1-phase 120Volt
80A (high) 40A (low)
@ Split-phase 240Volt
40A (high) 20A (low)
@ 3-phase 208Volt (4-Wire WYE)
26.8 A (high) 13.4A (low)
Available Wind Ratings:
75mph, 90mph, 120mph
75mph, 90mph, 120mph
UV & Flame Resistant Fabrics:
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
Floor Coverage:
216 sq ft
216 sq ft
Seating Capacity:
22 persons
22 persons
Dimensions:
17' 5 ¾\" (L)
12' 4 ½\" (W)
12' 1\" (H)
17' 5 ¾\" (L)
12' 4 ½\" (W)
12' 1\" (H)
Heating System:
10 x Non Glowing Radiant Panels
with 2-stage heat output
10 x Non Glowing Radiant Panels
with 2-stage heat output
Lighting System:
4 x Dimmable LED fixtures
4 x Dimmable LED fixtures
Electrical Power:
12kW (high heat)
6kW (low heat)
12kW (high heat)
6kW (low heat)
Electrical Current Loads:
@ 1-phase 120Volt
100A (high) 50A (low)
@ Split-phase 240Volt
50A (high) 25A (low)
@ 3-phase 208Volt (4-Wire WYE)
33.4 A (high) 16.7A (low)
@ 1-phase 120Volt
100A (high) 50A (low)
@ Split-phase 240Volt
50A (high) 25A (low)
@ 3-phase 208Volt (4-Wire WYE)
33.4 A (high) 16.7A (low)
Available Wind Ratings:
75mph, 90mph, 120mph
75mph, 90mph, 120mph
UV & Flame Resistant Fabrics:
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
Floor Coverage:
313 sq ft
313 sq ft
Seating Capacity:
32 persons
32 persons
Dimensions:
21' 8\" (L)
14' 5 ¼\" (W)
13' 3\" (H)
21' 8\" (L)
14' 5 ¼\" (W)
13' 3\" (H)
Heating System:
16 x Non Glowing Radiant Panels
with 2-stage heat output
16 x Non Glowing Radiant Panels
with 2-stage heat output
Lighting System:
4 x Dimmable LED fixtures
4 x Dimmable LED fixtures
Electrical Power:
19.2kW (high heat)
9.6kW (low heat)
19.2kW (high heat)
9.6kW (low heat)
Electrical Current Loads:
@ 1-phase 120Volt
160A (high) 80A (low)
@ Split-phase 240Volt
80A (high) 40A (low)
@ 3-phase 208Volt (4-Wire WYE)
53.4 A (high) 26.7A (low)
@ 1-phase 120Volt
160A (high) 80A (low)
@ Split-phase 240Volt
80A (high) 40A (low)
@ 3-phase 208Volt (4-Wire WYE)
53.4 A (high) 26.7A (low)
Available Wind Ratings:
75mph
75mph
UV & Flame Resistant Fabrics:
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
Floor Coverage:
198 sq ft
198 sq ft
Seating Capacity:
20 persons
20 persons
Dimensions:
14' ¾\" (L)
14' ¾\" (W)
11' 4\" (H)
14' ¾\" (L)
14' ¾\" (W)
11' 4\" (H)
Heating System:
8 x Non Glowing Radiant Panels
with 2-stage heat output
8 x Non Glowing Radiant Panels
with 2-stage heat output
Lighting System:
4 x Dimmable LED fixtures
4 x Dimmable LED fixtures
Electrical Power:
9.6kW (high heat)
4.8kW (low heat)
9.6kW (high heat)
4.8kW (low heat)
Electrical Current Loads:
@ 1-phase 120Volt
80A (high) 40A (low)
@ Split-phase 240Volt
40A (high) 20A (low)
@ 3-phase 208Volt (4-Wire WYE)
26.8 A (high) 13.4A (low)
@ 1-phase 120Volt
80A (high) 40A (low)
@ Split-phase 240Volt
40A (high) 20A (low)
@ 3-phase 208Volt (4-Wire WYE)
26.8 A (high) 13.4A (low)
Available Wind Ratings:
75mph, 90mph
75mph, 90mph
UV & Flame Resistant Fabrics:
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109
US National Code
ASTM E84 Class A
NFPA 701 Method 1
California
CSFM Title 19
New York City
MEA-150-05-M (OTCR)
Canadian National Code
ULC S-109